Ransburg PulseTrack2 A11515-XXXXX User Manual

Page 41

Advertising
background image

Brake Solenoid (bells only -

refer to Figures 6, 16, and 19)

1. Turn off AC Power to the control panel at the

Fused Disconnect and open the cabinet door.

2. Turn off supply air to the cabinet and bleed off

pressure.

3. Disconnect wires for each solenoid from their

termination points on J3 of the breakout board

and TB4.

4. Remove pneumatic tubing from solenoid as-

sembly “IN” and “EXH” ports, as well as from each

solenoid

output port.

5. Remove two mounting screws from solenoid

mounting manifold and remove assembly from

unit.

6. Remove two mounting screws from solenoid

end bracket.

7. Remove suspect solenoid and O-rings and

Figure 16: Brake Solenoid Disassembly

replace.

8. Reinstall the two mounting screws in the sole-

noid end bracket.

9. Reinstall the solenoid manifold assembly in

reverse order of disassembly. Wiring connections

should be made as follows:

Wire ID

From

TB4-4D

J3-25C

TB4-5D

J3-26C

TB4-6D

J3-27C

TB4-4D

J3-28C

TB4-5D

J3-29C

TB4-6D

J3-30C

COM

25C

COM

26C

COM

27C

COM

28C

COM

29C

COM

30C

To

SOL1-Bottom

SOL1-Top

SOL2-Bottom

SOL2-Top

SOL3-Bottom

SOL3-Top

SOL4-Bottom

SOL4-Top

SOL5-Bottom

SOL5-Top

SOL6-Bottom

SOL6-Top

10. Secure cabinet door and restore supply air

and AC power.

Advertising