Input power, Table 1 - ac input power connections, Temperature/humidity probe(s) (optional) – Ransburg PulseTrack2 A11515-XXXXX User Manual

Page 16

Advertising
background image

Figure 3: Optional Brake Control Valve Assembly (Bell Systems Only)

TB3-N

TB3-L

TB3-Ground

TABLE 1 - AC INPUT POWER

CONNECTIONS

Description

AC Neutral

AC Line (Hot)

Earth Ground

Connection Point

INPUT POWER

The AC Input power routing and connections to the

control panel should be supplied from a

FUSED

DISCONNECT rated 10 Amps/240VAC or great-

er, and should meet all guidelines of applicable

electrical codes and any other requirements as

suitable for the location. LOCKOUT/TAGOUT

procedures should be put in place for the fused

disconnect. Using conduit, route the input power

wiring, 14 AWG (2mm

2

/ 300V minimum) through

Temperature/Humidity Probe(s)
(Optional)

the AC Power opening in the top left corner of the

control panel. For greatest noise immunity the AC

input should be located as close as possible to the

AC line filter (see Figure 4). For this reason it is

recommended that the AC input

not be relocated

to another position on the control panel. Route

the input power wiring through the conduit and

attach to terminal block TB3 as shown in Table 1

and Figure 4.

>

After making the input power con-

nections, double-check to ensure that

the control panel is properly grounded by

measuring the resistance from one of the

Remote I/O connectors on the top of the

panel to an external ground reference.

The resistance should be less than 0.1

ohms.

C A U T I O N

!

>

The temperature/humidity probes

MUST

be located outside the hazardous area (see

NFPA-33).

W A R N I N G

!

Install the optional temperature/humidity probe(s)

in a desired area outside the hazardous location

such that the maximum length of cable from the

probe to the control panel does not exceed 250

ft. (76.2m). A 50 ft. (15.2m) cable assembly

is supplied with each probe. Additional 50 ft.

(15.2m) cable assemblies (p/n 77220-00) may be

purchased separately to extend this length up to

the 250 ft. (76.2m) maximum.

Advertising