Front panel bulbs, switches, or indicators, Ac line filter (see figure 15) – Ransburg PulseTrack2 A11515-XXXXX User Manual

Page 38

Advertising
background image

3. Open the small glass door and loosen the

mounting screws on the front of the card.

4. Remove the card from the unit and reinstall the

new card in reverse order of disassembly.

5. Ensure the SW2 DIP switch settings of a new

Atomizer Card are correct for the rotator in use

(see Figure 11 and Table 7).

6. Ensure the SW1 rotary DIP switch setting (see

Figure 11) is the same as the slot the card is in-

stalled in as shown on the label inside the cabinet

door.

7. Secure the cabinet door and restore AC power.

Front Panel Bulbs, Switches,
or Indicators

1. Turn off AC Power to the control panel at the

Fused Disconnect.

2. Open the cabinet door and pull up on the center

portion of the TB3-F1 and TB3-F2 terminal blocks

to open the AC line fuses.

3. Remove the contact block holder from the back

of the switch as follows:

a. For the AC power switch SW1 there is a

small lever that can be moved to the OFF

position to remove the contact and pilot light

blocks and block holder as one assembly. If

the contact or pilot light block needs replaced

refer to b. below for block removal from the

holder.

b. For the other switches and indicators, first

remove the contact or pilot light blocks from

the block holder, using a small screwdriver to

pry between the block and the numbered

portion of the holder (at this point, the contact

block, pilot light block or bulb can be replaced).

Then squeeze the clips of the holder together

slightly, pull back, and remove.

4. To replace a bulb, push in on the bulb and twist

counter-clockwise to remove.

5. To replace a switch or indicator, remove the

nut from the back of the switch or indicator and

remove the part from the door panel.

5. Replace with new parts and reinstall in reverse

order of disassembly.

6. Push fuses back in, secure cabinet door and

restore AC power.

AC Line Filter (See Figure 15)

1. Turn off AC Power to the control panel at the

Fused Disconnect.

2. Open the cabinet door and pull up on the center

portion of the TB3-F1 and TB3-F2 terminal blocks

to open the AC line fuses.

3. Remove the 5 quick connect terminals from

the filter.

4. Remove the filter mounting hardware.

5. Remove the filter and replace with a new one,

connecting the quick connect terminals as follows:

Color

From

TB3-F1
TB3-F2

TB3-Ground

SW1-B4
SW1-A3

Wire

ID

Light Blue

Black

Green/Yellow

Light Blue

Black

1
2

GND

4
5

To

Filter Terminal 1
Filter Terminal 3
Filter Terminal 2
Filter Terminal 4
Filter Terminal 5

6. Push fuse blocks back in, secure cabinet door

and restore AC power.