INSTALLATION

LOCATION

Control Panel

>

The PulseTrack 2 Control Panel

MUST

be located outside the hazardous area (see

NFPA-33).

>

This manual

MUST be read and thor-

oughly understood by

ALL personnel who

operate, clean, or maintain this equipment.

Special care should be taken to ensure that

the

WARNINGS and requirements for oper-

ating and servicing safely, are followed.

W A R N I N G

!

Install the control panel in a convenient area

outside the hazardous location, where it will be

protected from the possibility of any contact with

water, vapor or high humidity, and ambient tem-

peratures do not exceed 120°F (49°C). The area

should be clean, dry and well ventilated.

Brake Valve(s)
(Bells Only - Optional)

If a bell system is ordered with the brake option

an A11547 Brake Valve Assembly will be supplied

for each bell. Install the brake valve assembly(s)

on the LA0042 Air Manifold Assembly (supplied

separately) as follows (see Figure 3):

1. Remove the turbine air volume booster from

the manifold by loosening the swivel fitting.

2. Attach the swivel fitting of the brake valve

assembly to the manifold fitting.

3. Attach the swivel fitting of the turbine air volume

booster to the brake valve fitting.

The LA0042 Air Manifold should be mounted in a

convenient location such that the maximum tubing

lengths from the control panel to the brake valve

and the brake valve to the rotator do not each

exceed 100 ft. (30.5m).

>

Do not locate the control panel near

or adjacent to heat producing equipment

such as ovens, high wattage lamps,

steam pipes, etc.

C A U T I O N

!

Bolts or screws used for mounting must be at

least 3/8" (9.5mm) in diameter. If mounting to a

non-metallic wall, the mounting screws must be

secured to studs in the wall. If mounting to a metal

wall, the wall must be at least 0.100" (2.5mm) thick.