Gilderfluke&Co 8 Bit Digital Audio Systems User Manual

Page 38

Advertising
background image

¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥

"j" (5AA5)

Special Default Setup:

This command should not be used if there is more than one card in the

system. It loads the configuration EEprom with the default setups. As this sets
all cards to address 00, it can cause problems if invoked lightly. The '5AA5'
that follows the command is a key which keeps garbage from accidentally
issuing this command.

The values for the default settings are shown in the setup section of the

manual.

EXAMPLE: to do a Special Default Setup to the one and only card in

the system:

j5AA5

¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥

"k" (TRACK#)

LED Port Status:

This command responds with the following information for the card spec-

ified by the TRACK#:

BIT 0 = MUTE STATUS (1 = muted)
BIT 1 = DELAY STATUS (1 = in delay)
BIT 2 = HALF-MUTE STATUS (1 = half-muted)
BIT 3 = not used
BIT 4 = RUN STATUS (1 = running)
BIT 5 = STATUS OUTPUT STATUS (1 = on)
BIT 6 = PA STATUS (1 = on)
BIT 7 = REPEATER CLOCK ENABLED (1 = on)

EXAMPLE: to poll the LED Port Status for card 00:

k 0 0

38

¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥

"l" (TRACK#)

Switch Status:

This command responds with the following information for the card spec-

ified by the TRACK#:

BIT 0 = A INPUT STATUS (1 = closed)
BIT 1 = B INPUT STATUS (1 = closed)
BIT 2 = PB INPUT STATUS (1 = closed)
BIT 3 = not used
BIT 4 = not used
BIT 5 = not used
BIT 6 = not used
BIT 7 = not used

EXAMPLE: to poll the input Switch Status for card 00:

l 0 0

00

¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥¥

"m" (5AA5) (TRACK#)

Enter Configuration Mode:

This command puts the card specified by the TRACK# into the configura-

tion mode. All other cards in the system are locked off from receiving any
serial commands when there is even one card in setup mode. They will not
accept any serial commands until they hear the commands to exit setup
mode being sent to the one card which is in this mode. For details on the
setup mode, see the setup section of this manual.

EXAMPLE: to put card 00 into setup mode:

m5AA500

Note that only one card in the entire system is allowed to be in configura-

tion mode at one time. For this reason, if you try to put a card that doesnÕt
exist into configuration mode, not only will you not see a configuration
screen from that nonexistent card, no other card in the system will want to
listen to you until you take the nonexistent card out of configuration mode.

G

ILDERFLUKE

& C

O

.

¥

205 S. F

LOWER

¥

B

URBANK

, C

A

91502-2102

¥

818/840-9484

¥

800/776-5972

¥

F

AX

818/840-9485

30 of 72

Advertising