IAI America ISPDACR-ESD User Manual

Page 32

Advertising
background image

24

6SHFL¿FDWLRQ

(6) Loads applied to the actuator

[Standard types ISD/ISDA/ISPDA and cleanroom types ISDCR/ISPDCR/ISDACR/ISPDACR (excluding
ISPDCR-W/ISDACR-W/ISPDACR/W)]
Allowable load moments and allowable overhung load lengths of each actuator are shown below. Make
sure the applicable allowable values are not exceeded.

Allowable load moment (Nm)

Actuator Ma

Mb

Mc

S

28.4 N-m (2.9 kgf-m)

40.2 N-m (4.1 kgf-m)

28.4 N-m (2.9 kgf-m)

M

xMX

69.6 N-m (7.1 kgf-m)

99.0 N-m (10.1 kgf-m)

161.7 N-m (16.5 kgf-m)

L

xLX

104.9 N-m (10.7 kgf-m)

149.9 N-m (15.3 kgf-m)

248.9 N-m (25.4 kgf-m)

Allowable overhung load (L)

Actuator

Ma Direction

Mb Direction

Mc Direction

S

450 or less

450 or less

450 or less

M

xMX

600 or less

600 or less

600 or less

L

xLX

750 or less

750 or less

750 or less

The allowable overhangs assume that the center of gravity of the installed object is located at a position
one half the overhang length.

Mb or Mc direction

Direction of moment

Direction of allowable overhang

Ma direction

Advertising