Supplement – IAI America DS-S-T1 User Manual

Page 87

Advertising
background image

Page 85

(5) E0 - E3 programming errors Group 4/Command error - 3

These errors, like those in sections 3 and 4 above, primarily arise from the way the commands are used.

(6) EG error - Emergency Stop

If an EG alarm occurs, consider the following.

Q Emergency stop signal asserted

Determine what triggered the emergency stop and then release the emergency stop (press the button). During an
emergency stop, the ready signal or output 301 is OFF and the alarm or output 300 is ON. However, if the emergency
stop is asserted when the power is turned ON, alarm output 300 will not go ON. The 300 output functions after the
ready signal is given.

E0

Undefined command error

Attempted to execute an
use the PC interface softw
prevent this.

E1

Subroutine overnesting error

There are more than 15 s
alarm occurs after trying t
program so that the numb
less than 15. Also note th
use of the IF command, th
error.

E2

Subroutine under nesting error

BGSR is not paired with E
found before the EDSR.

E3

Controlling column error

The expansion condition i
using the PC software, it w
syntax error at the time of

Power ON

Emergency stop

Ready signal (301)

Alarm output (300)

11. Supplement