Mounting cased drives

Leeson cased drives come with three 0.88-inch (22 mm)
conduit knockout holes on the bottom of the case. The units
may be vertically wall mounted using the four 0.25-inch (6 mm)
slotted holes on the attached heat sink. For motor loads less
than 5 ADC, the drive may be bench mounted horizontally, or
operated without mounting.

1. Install the mounting screws.

2. For access to the terminal strip, turn the slotted screw on

the front cover counterclockwise until it is free from the
case. The right side of the cover is hinged to the case. Lift
or pull the slotted screw to open the case.

3. Carefully remove the conduit knockouts by tapping them

into the case and twisting them off with pliers.

4. Install conduit hardware through the 0.88 inch (22 mm)

conduit holes. Connect external wiring to the terminal block.

5. Grasp the slotted screw and tilt the front cover back into

place. Avoid pinching any wires between the front cover and
the case.

6. Turn the slotted screw clockwise until tight to secure the

front cover.

7. Set the POWER switch to the “O” or OFF position before

applying the AC line voltage.

7