Heat sinking, Ac line and motor connections, 8installation – LEESON Chassis Mount Regenerative Control: 175721.00 User Manual

Page 14

Advertising
background image

8

Installation

Heat sinking

Model 175721.00 requires an additional heat sink, p/n 175722,
when the continuous armature current is above 7 ADC. Model
175720.00 has sufficient heat sinking in its basic configuration.
Use a thermally conductive heat sink compound (such as Dow
Corning

®

340 Heat Sink compound) between the drive chassis

and the heat sink surface for optimum heat transfer.

AC line and motor connections

Use 12 AWG or 14 AWG standard wire for connecting the
line and the armature. Use 16 AWG or 18 AWG standard wire
when connecting the field of a shunt-wound motor. Strip the
wire insulation 0.25 inches (6 mm). See Figures 4 and 5 for
AC line (115 VAC or 230 VAC) and motor connections to
chassis and cased drives.

Figure 4. Chassis Drive Connections

AC INPUT

VOLTAGE

115 VAC

230 VAC

L1

GND

F1

F2

A2

A1

L2

115V

C505

TB502

TB501

SW501

C503

IC502

S3

S2

L2

230V

C504

FIELD OUTPUT

For shunt wound

motors only. See field

output section for details.

MOTOR