1

Specifications

Max.

Armature

HP Range

HP Range

Current

with 115 VAC

with 230 VAC

Model

(Amps DC)

Applied

Applied

175720.00

10.0 †

1/4 – 1 †

1/2 – 2 †

175721.00

10.0 †

1/4 – 1 †

1/2 – 2 †

† Maximum armature current and horsepower range apply when drive is attached to

additional heat sink part number 175722. Use heat sink when armature current is

above 7 ADC. Heat sinks are pre-mounted on cased drives.

AC Line Voltage

115/230 VAC, ±10%, 50/60 Hz, single phase

Armature Voltage (115 VAC Input)

0 – 90 VDC

Armature Voltage (230 VAC Input)

0 – 180 VDC

Form Factor

1.37 at base speed

Field Voltage (115 VAC Input)

50 VDC (F1 to L1); 100 VDC (F1 to F2)

Field Voltage (230 VAC Input)

100 VDC (F1 to L1); 200 VDC (F1 to F2)

Max. Field Current

1 ADC

Accel. Time Range (with no load)

0.5 –10 seconds

Decel. Time Range (with no load)

0.5 –10 seconds

Analog Input Voltage Range (isolated; RB1 to S2)

0 –10 VDC

Input Impedance (S0 to S2)

32K ohms

Load Regulation

with Armature Feedback

1% of base speed or better

with Tachogenerator Feedback

0.1% of base speed

Ambient Temp. Range (chassis drive)

10°C – 55°C

Ambient Temp. Range (cased drive)

10°C – 40°C