Alarms for power failure – LevelOne IES-1085 User Manual

Page 18

Advertising
background image

User Manual

Page 18

Step 2: Disconnect the power cord if you want to shut down the switch.


Back View

Alarms for Power Failure

Step 1: There are two pins on the terminal block used for power failure detection. It

provides the normally closed output when the power source is active. Use this as a
dry contact application to send a signal for power failure detection.

Term

inal Bl

ock

PW1

+

47 57VDC

Power Ground

PW2

+

47 57VDC

Power Ground

Earth Ground

Relay Output

1A @ 250VAC

Relay Alarm warning signal disable for following:
3. The relay contact closes if Power1 and Power2 are both failed but Power3 on
4. The relay contact closes if Power3 is failed but Power1 and Power2 are both on

DC

Jack

PW3

DC Jack

47 to 57VDC



Special note:
The relay output is normal open position when there is no power to the switch.
Please do not connect any power source to this terminal to prevent shorting your
power supply.