Onsole, Onfiguration, Console configuration – LevelOne IES-1085 User Manual

Page 8

Advertising
background image

User Manual

Page 8

Console Configuration

 Connect to the switch console:

Connect the DB9 straight cable to the RS-232 serial port of the device and the RS-232
serial port of the terminal or computer running the terminal emulation application.
Direct access to the administration console is achieved by directly connecting a
terminal or a PC equipped with a terminal-emulation program (such as HyperTerminal)

to the switch console port.

 Configuration settings of the terminal-emulation program:

Baud rate: 115,200bps
Data bits: 8
Parity: none

Stop bit: 1
Flow control: none

 Press the Enter key. The Command Line Interface (CLI) screen should appear as below:

 Logon to Exec Mode (View Mode):

Mode (or View Mode).

>

 Logon to Privileged Exec Mode (Enable Mode):

screen.

 Logon to Configure Mode (Configure Terminal Mode):

will show on the screen.

 Set new IP address and subnet mask for Switch:

interface vlan1.1

logon to vlan 1 (vlan1.1 means vlan 1).

-if

on the screen.
Command Syntax:

.

specifies IP address. M specifies IP

subnet mask. M = 8: 255.0.0.0, 16:255.255.0.0, or 24: 255.255.255.0.

For example,

-if

ip address

192.168.1.10/24

set new IP address (192.168.1.10) and new IP

subnet mask (255.255.255.0) for Switch.

Advertising