Bit)(testf.15.3) – Teledyne LeCroy SAS Sample Test Suite User Manual

Page 104

Advertising
background image

SAS Sample Test Suite

Behavior After Receiving a Task Management Request (Test Group F)

104

SCSI CDB – Identical Read command sequence with TAG Conflict (no retran bit)(TestF.15.3)

Test Procedure:

1. The Testing Station is instructed to start and complete a phy Reset sequence followed by an

Identify sequence with the DUT. Since the DUT is a target, the Testing Station is instructed

to transmit an Identify Address frame indicating that it is a SAS Initiator.

2. The Testing Station is instructed to open an SSP connection to the DUT and transmit a SCSI

READ command for 512 bytes w/TAG = 0018. Close the connection..

3. Before DUT responds, the Testing Station is instructed to open an SSP connection to the

DUT and transmit an identical SCSI READ command as first Write w/TAG = 0018. Close the

connection.

Observable Results: Verify that the DUT responds to the duplicate write with a response of Status

CHECK CONDITION, Sense Key of ABORT COMMAND and ASC/Q of OVERLAPPING COMMANDS

ATTEMPTED.

4. The Testing Station is instructed to open a connection to the DUT and transmit a Test Unit

Ready command frame w/TAG = 001A.

Observable Results: Verify that the DUT responds to the TUR data sequence with a Status=Good

w/TAG = 001A