SAS Sample Test Suite
Error Conditions – Frames Received from Initiator (Test Group C)
49
Figure 18 - Data Offset sequence error (Missing, Duplicate, Out of Order)
Initiator/Test Station
Target Primitive Logic
Target Protocol Logic
Write Command
SSP Link
SAS Protocol
XFER
READY
ACK Primitive
ACK Primitive
SAS Protocol
SSP Link
ACK Primitive
SSP Link
RESPONSE
OFFSET values for
each test
Missing
Duplicate
Order
0000...0000…0000
0200...0200...0600
---- …0200…0200
0600…0400…0400
---- ….0600…0600
Error Detected
Status: CHECK CONDITION
Sense = 0xB (Aborted Command)
ASC/ASCQ = 0x4B05 (Data Offset Error)
DATA
DATA
DATA
DATA