Teledyne LeCroy SAS Sample Test Suite User Manual

Page 49

Advertising
background image

SAS Sample Test Suite

Error Conditions – Frames Received from Initiator (Test Group C)

49

Figure 18 - Data Offset sequence error (Missing, Duplicate, Out of Order)

Initiator/Test Station

Target Primitive Logic

Target Protocol Logic

Write Command

SSP Link

SAS Protocol

XFER

READY

ACK Primitive

ACK Primitive

SAS Protocol

SSP Link

ACK Primitive

SSP Link

RESPONSE

OFFSET values for
each test

Missing

Duplicate

Order

0000...0000…0000



0200...0200...0600



---- …0200…0200




0600…0400…0400


---- ….0600…0600

Error Detected

Status: CHECK CONDITION
Sense = 0xB (Aborted Command)
ASC/ASCQ = 0x4B05 (Data Offset Error)

DATA

DATA

DATA

DATA