4. Start the Trainer GUI (Pull down “View” select “Show Trainer File” or hit the Trainer button)

and configure the port setting by select the Pull down “Setup” and slecting “Port
Configuration”. Change port Assignment to AT, -, -, - and save with OK.

5. Open a Trainer script (Pull down “file” select “Open” or Open Button) and select test script

from directory Trainer/TestScript.

6. To start the test, initiate the analyzer trace capture (Start Analyzer button (Red Dot button))

then start Generator (Pull down “Generate” select “Start Generate” or hit the Start
Generate button). The test is started.

7. View the Trainer Port “Show Port Status” screen (Hit the lower right Green/Red LED looking

to open window) to view the capture and trainer status value. Trainer column will display
the test results. Stop Analyzer (Red Square button) to view captured trace.

Test Script Result Values
The test scripts will return a status value of the following:

0. NO RESULT: System error condition discovered with selected Test.
1. PASSED: Test completed with expected results.
2. FAILED: Test completed but with unexpected or invalid SAS events.
3. SETUP ERROR: Test was unable to establish DUT state for proper test condition.

Failed or Setup can be investigated by viewing the captured trace file. Each of the failed tests can

be re-tested to see if an internal condition in the DUT could have cleared itself.