Error Conditions – Frames Received from Initiator (Test Group C)

50

Write Data Request with data framing errors (TestC.19 )
SSP_DATA_IU – Write request with Data Timeout response (TestC.19)
An initiator that request a Write but does not send any data will require the DUT to initiate an

Abort to the command.

Test Procedure:

1. The Testing Station is instructed to start and complete a phy Reset sequence followed by an

Identify sequence with the DUT. Since the DUT is a target, the Testing Station is instructed
to transmit an Identify Address frame indicating that it is a SAS Initiator.

2. The Testing Station is instructed to open an SSP connection to the DUT and transmit a SCSI

WRITE command for 2048 bytes. Close the connection

3. Allow the DUT to open an SSP connection to the Testing Station and transmit XFER_RDY.
4. The Testing Station is instructed to wait for the DUT to timeout and send response.

Observable Results: Verify that the DUT responds to the write data sequence with a CHECK

CONDITION and ASC/Q = 0x4B06 (Initiator Response Timeout)