Testf.15.5) – Teledyne LeCroy SAS Sample Test Suite User Manual

Page 108

Advertising
background image

SAS Sample Test Suite

Behavior After Receiving a Task Management Request (Test Group F)

108

SCSI CDB – Write and Query TASK command sequence with same TAG Conflict (TestF.15.5)

Test Procedure:

1. The Testing Station is instructed to start and complete a phy Reset sequence followed by an

Identify sequence with the DUT. Since the DUT is a target, the Testing Station is instructed

to transmit an Identify Address frame indicating that it is a SAS Initiator.

2. The Testing Station is instructed to open an SSP connection to the DUT and transmit a SCSI

WRITE command for 512 bytes w/TAG = 0018. Close the connection..

3. Before DUT responds, the Testing Station is instructed to open an SSP connection to the

DUT and transmit a QUERY TASK command w/TAG = 0018. Close the connection.

Observable Results: Verify that the DUT responds to the duplicate write with a response of Status

CHECK CONDITION, Sense Key of ABORT COMMAND and ASC/Q of OVERLAPPING COMMANDS

ATTEMPTED.

4. The Testing Station is instructed to open a connection to the DUT and transmit an ABORT

TASK command w/TAG = 0019. Close the connection.

Observable Results: Verify that the DUT responds to the ABORT TASK sequence with a Status TMF

Completed w/TAG = 0019.

Advertising