Teledyne LeCroy SAS Sample Test Suite User Manual

Page 48

Advertising
background image

SAS Sample Test Suite

Error Conditions – Frames Received from Initiator (Test Group C)

48

b. Offset 0000, 0200, 0200, 0400 and 0600.

c. Offset 0000, 0200, 0400, 0400 and 0600.

d. Offset 0000, 0200, 0400, 0600 and 0600.(optional)

Observable Results: Verify that the DUT responds to the Write data sequence with a Response of

CHECK CONDITION and ASC/Q = 0x4B05 (Data Offset Error)

SSP_FRAMES – Data Offset Sequence error Out of Order sequence frame (TestC.18)

Test Procedure:

1. The Testing Station is instructed to start and complete a phy Reset sequence

followed by an Identify sequence with the DUT. Since the DUT is a target, the Testing
Station is instructed to transmit an Identify Address frame indicating that it is a SAS
Initiator.

2. The Testing Station is instructed to open an SSP connection to the DUT and transmit

a SCSI WRITE command for 2048 bytes. Close the connection

3. Allow the DUT to open an SSP connection to the Testing Station and transmit

XFER_RDY.

4. The Testing Station is instructed to open a connection to the DUT and transmit the

2048 bytes of data. Send 5 DATA frames of 512 bytes each with Offset 0000, 0600,
0200, 0400 and 0600.

Observable Results: Verify that the DUT responds to the write data sequence with a Response of

CHECK CONDITION and ASC/Q = 0x4B05 (Data Offset Error)

Advertising