Errors on data frames (testb.3 & testb.4), Nak response from initiator (testb.3) – Teledyne LeCroy SAS Sample Test Suite User Manual

Page 17

Advertising
background image

SAS Sample Test Suite

Error Conditions – Frames Sent to Initiator (Test Group B)

17

Errors on DATA frames (TestB.3 & TestB.4)

NAK response from Initiator (TestB.3)
Target device shall send a Response frame with Check Condition status, sense key = Aborted

Command, and

additional sense code = NAK RECEIVED. This Response frame may be sent in the same or in a new

connection.

Test Procedure:

1. The Testing Station is instructed to start and complete a phy Reset sequence

followed by an Identify sequence with the DUT. Since the DUT is a target, the Testing
Station is instructed to transmit an Identify Address frame indicating that it is a SAS
Initiator.

2. The Testing Station is instructed to open an SSP connection to the DUT and transmit

a SCSI READ(10) command for 1 frame. Close the connection

3. Allow the DUT to open an SSP connection to the Testing Station and transmit DATA

frames. The Testing Station is instructed to transmit a NAK to the DATA frame.

Observable Results: Verify that the DUT transmits a SCSI response Abort with sense key of

ABORTED COMMAND and sense code of NAK RECEIVED.