Vanguard DMOM‐600 User Manual
Page 15

REV 2 Auto‐Ohm 200 S3 / DMOM‐200 S3 / DMOM‐600 USER’S MANUAL
11
1.7
DMOM-600 Technical Specifications
Table 3. DMOM-600 Technical Specifications
TYPE
Portable Micro-Ohmmeter
PHYSICAL SPECIFICATIONS
16.8” W x 12.6” H x 12” D (42.7cm x 32cm x 30.5cm); Weight: 33 lbs (15 Kg)
INPUT POWER 100-120 Vac, 20A, 50/60 Hz – Up to 300A load
220-240 Vac, 20A, 50/60Hz – Up to 600A load
RESISTANCE READING
RANGE
1 milliohm at 600A to 450 milliohms at 10A
ACCURACY
10A to 49.9A: 1% ±2 micro-ohms
50A to 600A: 1% ±1 micro-ohm
TEST CURRENT RANGE
10 Amperes to 600 Amperes (selectable in 1A steps)
DISPLAY
Backlit LCD (128 x 64 pixels), viewable in direct sunlight and low light levels
KEYPAD
Rugged, 44key "QWERTY" membrane keypad
INTERNAL TEST RECORD
STORAGE
128 test records. Each record can contain up to 64 readings
EXTERNAL TEST RECORD
STORAGE
Up to 999 test records on external USB Flash drive.
COMPUTER INTERFACE
RS-232C
PRINTER Built-in 2.5” wide thermal printer
PC SOFTWARE Windows XP/Vista/7 Analysis Software (included with purchase)
SAFETY
Designed to meet IEC 61010 (1995), UL 61010a, and CASC22.2 standards
ENVIRONMENT Operating: 10˚C to 50˚C (15˚F to +122˚F)
Storage: 30˚C to 70˚C (22˚F to +158˚F)
HUMIDITY (MAX) 90% RH @ 40˚ C (104˚ F) non-condensing
ALTITUDE (MAX) 2000m (6562 ft) to full safety specifications
CABLES 15 ft (4.6 m), #1/0 AWG test cables, power cord, ground cable
OPTIONS Shipping case, C-Clamp set, Hand Spike Set, Dual Ground option
WARRANTY One year on parts and labor
NOTE
The above specifications are valid at nominal operating voltage and at a
temperature of 25C (77F). Specifications may change without prior notice.