Vanguard DigiTMR S2 User Manual
Page 75

REV 1 DIGITMR S2 USER’S MANUAL
70
c. The following screen will be displayed while the graph is being printed:
Figure 17 shows a CLOSE timing chart of a circuit breaker with contact activity on
channels 1 and 3. A CT channel is also shown on the chart. Since the printout was
generated to show both Quick-Shot Mode and Time-Travel Mode, both the CT time and
Contact-Travel readings are shown on the chart.
NOTES
• If the results are from a test using the 1 second window, the graph will
be from 0 to 1000 ms with 50 ms time markers.
• If the results are from a test using the 10 second window, the graph will
be from 0 to 10 sec with 500 ms time markers.
• If the results are from a test using the 20 second window, the graph will
be from 0 to 20 sec with 1 second time markers.
d. When the printer is done printing the graphic test results, you will be returned to the
“START-UP” menu.
PLEASE WAIT
PLOTTING GRAPH