NANO-LX EPIC SBC

Page 77

JP3

Description

1-2

UART-2 RxD Signal connect to RS-422 (Default)

2-3

UART-2 RxD Signal connect to RS-485

Table 5-4: JP3 Jumper Settings

5.6.4 AT/ATX Power Mode Select Jumper

Jumper Label:

JP4

Jumper Type:

2-pin header

Jumper Settings:

See Table 5-5

Jumper Location:

See Figure 5-4

The JP4 jumper block controls the connection to a power supply.

The CN5 connector is used to connect a chassis power On/Off button using an adapter

cable and is configured through the JP4 jumper. The CN5 connector has two operational

modes:

Using

ATX power: CN5 connects to an externally implemented power switch,

and the JP4 jumper should be left open.

Using

AT power: The pins on JP4 are shorted by a jumper cap. JP4 should be

shorted by default as the AMD® Southbridge is designed without the

consideration for a power button signal. The shorted JP4 provides a hardware

feedback to initiate the system. The power on/off function is then managed by

the AT power switch button.

JP4

Description

Short AT

Mode

(Default)

Open ATX

Mode

Table 5-5: JP4 Jumper Settings