4 at/atx power mode select jumper, Table 5-4: jp3 jumper settings, Table 5-5: jp4 jumper settings – IEI Integration NANO-LX v1.21 User Manual
Page 92: See table 5-4

NANO-LX EPIC SBC
Page 77
JP3
Description
1-2
UART-2 RxD Signal connect to RS-422 (Default)
2-3
UART-2 RxD Signal connect to RS-485
Table 5-4: JP3 Jumper Settings
5.6.4 AT/ATX Power Mode Select Jumper
Jumper Label:
JP4
Jumper Type:
2-pin header
Jumper Settings:
Jumper Location:
The JP4 jumper block controls the connection to a power supply.
The CN5 connector is used to connect a chassis power On/Off button using an adapter
cable and is configured through the JP4 jumper. The CN5 connector has two operational
modes:
Using
ATX power: CN5 connects to an externally implemented power switch,
and the JP4 jumper should be left open.
Using
AT power: The pins on JP4 are shorted by a jumper cap. JP4 should be
shorted by default as the AMD® Southbridge is designed without the
consideration for a power button signal. The shorted JP4 provides a hardware
feedback to initiate the system. The power on/off function is then managed by
the AT power switch button.
JP4
Description
Short AT
Mode
(Default)
Open ATX
Mode
Table 5-5: JP4 Jumper Settings