System fan replacement, Ystem, Eplacement – IEI Integration RPC-6022G User Manual
Page 70: Figure 5-3: system fan retention screws, 6 system fan replacement

RPC-6022GW Rackmount LCD Workstation
Page 70
Step 1:
Step 2:
Step 3:
Step 4:
Step 5:
Step 6:
Step 7:
Step 8:
5.6 System Fan Replacement
To replace the system fan, please follow the instructions below.
CAUTION:
Carefully note the direction and orientation of the existing system fan prior to
replacement.
Turn off and disconnect the workstation from all power sources.
Remove the workstation from the rack in which it is installed.
Open the top cover of the RPC-6022GW Rackmount LCD Workstation.
(See Section 4.5.1)
Disconnect the system fan from the PSU.
Remove the CPU card clamp (See Section 4.5.2).
Remove the defective cooling fan by removing two screws that secure the fan to
the CPU card clamp (Figure 5-3).
Figure 5-3: System Fan Retention Screws
Install the new system fan. Secure the fan with retention screws.
Connect the new system fan to the PSU.