Disk drive replacement, 5” or 5.25” disk drive, Rive – IEI Integration RPC-6022G User Manual

Page 74: Eplacement, 1 3.5” or 5.25” disk drive, 8 disk drive replacement

Advertising
background image

RPC-6022GW Rackmount LCD Workstation

Page 74

Step 8:

Step 9:

Step 10:

Step 11:

Step 12:

Step 13:

Step 1:

Step 2:

Step 3:

Step 4:

Step 5:

Step 6:

Step 7:

Step 8:

Remove the defective cooling fan.

Install the new cooling fan to the fan bracket. Secure the fan with retention

screws.

Pull the fan bracket toward the front panel.

Connect the new cooling fan to the PSU.

Secure the fan bracket with screws removed earlier.

Close the top cover of the workstation and reinstall the workstation into the

cabinet or rack in which it was previously installed. Refer to Section 4.6 for

complete mounting instructions.

Step 0:

5.8 Disk Drive Replacement

5.8.1 3.5” or 5.25” Disk Drive

To replace a disk drive, please follow the instructions below.

Turn off and disconnect the workstation from all power sources.

Remove the workstation from the rack in which it is installed.

Open the top cover of the RPC-6022GW Rackmount LCD Workstation.

(See Section 4.5.1)

Disconnect all cabling from every hard drive.

Remove the drive bracket (see Section 4.5.3).

Remove the retention screws that secure the disk drive to the drive bracket and

slide the drive out of the bracket.

Install the new disk drive. (See Section 4.5.5)

Reinstall the drive bracket to the workstation. (See Section 4.5.6)