Controller Warnings

Check controller instruction sheet for latest controller

updates and troubleshooting codes. Controller instruc-

tion sheet is inside controller shipping box.
IMPORTANT! INSTALLER, DO NOT DISCARD

CONTROLLER INSTRUCTION SHEET. STAPLE SHEET

TO SPREADER MANUAL AND GIVE TO END USER!
Note:
To unclog auger manually, first remove the chute.

Apply 1¼" open wrench on auger’s nut. Turn auger

counterclockwise several times.
Note: Do not run the vibrator longer than 30 minutes

with 15 minutes between runs to avoid overheating.

Spreader Maintenance

1. Wash spreader after every use. Make sure no mate-

rial is left under auger and/or inside trough.

2. Inspect and retighten fasteners after every 5-7 hours

of operation.

3. Lubricate bearing every 7-10 hours of operation using

general automotive grease.

4. Inspect terminals/connectors every time you discon-

nect spreader from wire harness. Apply thin layer

of dielectric grease on terminals. If any tarnish/cor-

rosion is found, clean terminals and apply dielectric

grease.

5. Use dielectric grease on all electrical connectors

before an electrical connection is made or after con-

nector is disconnected

6. Grease and spray with lubricant Auger bearing after

every 20 hours of use.

7. Empty the spreader of all ice control materials when

not in use. Wash out the spreader to prevent material

builds up.

8. It is recommended to cover spreader with the tarp

during storage periods. Tarp can be attached to

anchors on both sides of tie downs.

End of Season Maintenance

1. Wash spreader. Make sure no material or residue is left

in and outside the hopper.

2. Lubricate bearing using general automotive grease.
3. Inspect wire harness, connectors for broken insulation,

missing components. Replace if necessary.

4. Apply dielectric grease on all electrical connectors.
5. Store hopper indoors, in a dry, cool place.
6. Remove controller from truck. Store controller indoors,

in a dry, cool place.

Summer Storage

1. Apply dielectric grease or similar protective compound

on all electrical connectors & protect them with caps

before storage.

2. Disconnect and remove speed controller from vehicle

and store it in dry and cool place. Protect controller

from excessive heat and moisture.

3. Clean hopper and trough from all kinds of debris.
4. Remove, thoroughly lubricate and reinstall trough

bearing.

5. Protect hopper from excessive temperatures during

summer storage.

WARNING

Always disconnect power when servicing spreader.

CONNECT

CONNECT

CONNECT

CONTROLLER #3014199

WIRE 36" LONG

#0203700

POWER CABLE

#3006842

MAIN WIRE

HARNESS #3006724

FUSE CONNECTOR

CONNECT TO FUSE

TERMINAL OR

IGNITION SWITCH

CONNECT TO

BATTERY

CONNECT TO CHUTE

CONNECT TO MOTOR

OPTIONAL

# 3018009

COMPARTMENT HARNESS

BROWN WIRE

CONNECT TO

UTILITY LIGHT

CONNECT TO

KNOWN GROUND

Advertising