Oit #1 oit #100, Oit #2 – Maple Systems STEPware-100 User Manual

Page 20

Advertising
background image

OIT Jumper
All of the OITs, except the OIT3100 and OIT4100 Series, have a jumper that must be

moved when connecting the OIT to a network. Refer to the Set Jumper for Specific

Protocol section in the OIT Installation Manual.

OIT Connection

Getting Started

17

1010-0096, Rev. 04

HOST

Less than

4000'

TO OIT

Less than 12"

Shielded Cable

OIT #1

OIT #100

TERMINA

TOR

TERMINA

TOR

To More

OITs

OIT #2

From Host or

Previous OIT

See

Detail A & B

Detail B

5 Wire Termination

Detail A

5 Wire Termination

To More

OITs

From Host or

Previous OIT

CHASSI

S

GND

RXD+/

TXD+

RXD-

/T

XD-

SI

G

GND

SI

G

GND

CHASSI

S

GND

RXD-

SI

G

GND

TXD+

TXD-

TO OIT

CHASSI

S

GND

TXD+

TXD-

RXD+

RXD-

SI

G

GND

SI

G

GND

RXD+

Drain

Wires

2 Pair Twisted

Shielded Cable

24 Gage Wire

3 Pair Twisted

Shielded Cable

24 Gage Wire

Drain

Wires