Local echo setting, Block echo setting, Turn-around delay setting – Maple Systems STEPware-100 User Manual

Page 32

Advertising
background image

Local Echo Setting

This parameter determines whether local echo is used when the OIT is operating in

Interactive mode. If enabled, each character sent to the host controller from an OIT

keypress is also sent to the OIT’s display.
To modify this parameter using STEPware-100:
1. Open the Configuration Editor.
2. In the OIT Operational Settings group box, select the Local Echo Enabled check box.
To modify this parameter in Configuration mode:
1. At Local Echo:, use the OIT’s TOGGLE key to enable or disable local echo. Refer to

the Configuration Mode section in this chapter for more information.

To modify this parameter from the host controller:
1. Use the Display Format Control control command. Refer to Appendix A: Control

Commands for more information.

Block Echo Setting

This parameter determines whether block echo is used when the OIT is operating in

Block or Network mode. If enabled, each character sent to the host controller from an

OIT keypress is also sent to the OIT’s display. If disabled, asterisks are sent to the OIT’s

display in place of the characters.
To modify this parameter using STEPware-100:
1. Open the Configuration Editor.
2. In the OIT Operational Settings group box, select the Block Echo Enabled check box.
To modify this parameter in Configuration mode:
1. At Block Echo:, use the OIT’s TOGGLE key to enable or disable block echo. Refer to

the Configuration Mode section in this chapter for more information.

To modify this parameter from the host controller:
1. Use the Display Format Control control command. Refer to Appendix A: Control

Commands for more information.

Turn-Around Delay Setting

This parameter determines the amount of time the OIT waits to respond after receiving a

command from the host controller. Options are No Delay, 50 msec, 100 msec, or 250

msec. Be sure to pick a turnaround delay that allows the host controller enough time to

prepare for the OIT’s response.
To modify this parameter using STEPware-100:
1. Open the Configuration Editor.
2. In the OIT Operational Settings group box, select the desired turn-around delay in the

Turn-Around Delay list box.

OIT Configuration

29

1010-0096, Rev. 04