Network Address Setting

This parameter determines the network address used by the host controller to

communicate with this OIT when in Network mode. Options are 1 to 255.
To modify this parameter using STEPware-100:
1. Open the Configuration Editor.
2. In the OIT Operational Settings group box, enter the desired network address in the

Network Addr. text box.

To modify this parameter in Configuration mode:
1. At Network Address:, use the OIT’s TOGGLE key to select the desired network

address. Refer to the Configuration Mode section in this chapter for more

information.

To modify this parameter from the host controller:
1. Use the Set Operating Mode control command. Refer to Appendix A: Control

Commands for more information.

Tab Width Setting

This parameter determines how many spaces the OIT moves the cursor when the HT

control code (hexadecimal 09) is received from the host controller. Options are 1 Space, 4

Spaces, and 8 Spaces.
To modify this parameter using STEPware-100:
1. Open the Configuration Editor.
2. In the OIT Operational Settings group box, select the desired tab width in the Tab

Width list box.

To modify this parameter in Configuration mode:
1. At Tab Width:, use the OIT’s TOGGLE key to select the desired tab width. Refer to

the Configuration Mode section in this chapter for more information.

To modify this parameter from the host controller:
1. Use the Set Tab Character Width control command. Refer to Appendix A: Control

Commands for more information.

Cursor Type Setting

This parameter determines the type of cursor used in the OIT’s display. Options are No

Cursor and Underline.
To modify this parameter using STEPware-100:
1. Open the Configuration Editor.
2. In the OIT Operational Settings group box, select the desired cursor type in the

Cursor Type list box.

To modify this parameter in Configuration mode:
1. At Cursor:, use the OIT’s TOGGLE key to select the desired cursor type. Refer to the

Configuration Mode section in this chapter for more information.

OIT Configuration