<2. Handling Cautions>

2-10

IM 01C25T02-01E

WARNING

• Electrostatic charge may cause an exlosion

hazard. Avoid any actions that cause the

gerenation of eletrostatic charge, such as

rubbing with a dry cloth on coating face of

the product.

• In the case where the enclosure of the

Pressure Transmitter is made of aluminium,

if it is mounted in an area where the use of

category 2D apparatus is required, it shall

be installed in such a way that the risk from

electrostatic discharges and propagating

brush discharges caused by rapid flow of

dust is avoided.

• The instrument modification or parts

replacement by other than an authorized

Representative of Yokogawa Electric

Corporation is prohibited and will void the

certification.

• To satisfy IP66 or IP67, apply waterproof

glands to the electrical connection port.

c. ATEX Intrinsically Safe Ex ic
Caution for ATEX Intrinsically safe Ex ic

The transmitters with option code /KN26 for

potentially explosive atmospheres:

• Applicable Standard:

EN 60079-0:2009/EN 60079-0:2012,

EN 60079-11:2012

• Type of Protection and Marking Code:

II 3G Ex ic IIC T4 Gc

• Ambient Temperature: –30* to +60°C

* –15°C when /HE is specified.

• Maximum Process Temperature: 120°C

• Ambient Humidity:

0 to 100% (No condensation)

• IP Code: IP66

• Ambient pollution degree: 2

• Overvoltage category: I

Note 1. Electrical Data

Ui = 32 V

Ci = 3.52 nF

Li = 0 µH

Note 2. Installation

• All wiring shall comply with local installation

requirements. (refer to the control drawing)

• When installing the transmitter in “ic”

FISCO system or FNICO system, follow the

installation requirements of each system.

• Cable glands, adapters and/or blanking

elements shall be of Ex “n”, Ex “e” or Ex “d”

and shall be installed so as to maintain the

specified degree of protection (IP Code) of

the transmitters.

Note 3. Maintenance and Repair

• The instrument modification or parts

replacement by other than authorized

representative of Yokogawa Electric

Corporation is prohibited and will void ATEX

intrinsically safe.

Associated

Apparatus

Transmitter

Nonhazardous Area

[Control drawing]

Hazardous Area

+

F0208.ai

• Above drawing shows the installation of

Entity system.

When installing the transmitters in “ic”

FISCO system or FNICO system, follow the

installation requirements of each system.

Note 4. Specific Conditions of Use

WARNING

• Electrostatic charge may cause an explosion

hazard. Avoid any actions that cause the

gerenation of eletrostatic charge, such as

rubbing with a dry cloth on coating face of

the product.

• When the lightning protector option is

specified, the apparatus is not capable

of withstanding the 500V insulation test

required by EN60079-11. This must be taken

into account when installing the apparatus.

Advertising