A7.9 System/Network Management VFD Parameters Relating to

Software Download

Table A7.5 System/Network Management VFD Parameters

Write Mode: R/W = read/write; R = read only

Index

(SM)

Parameter

Name

Sub

Index

Sub-parameter Name

Default

(Factory Set)

Write

Mode

Remarks

400 DWNLD_

PROPERTY

0

R

1

Download Class

1

2

Write Rsp Returned For ACTIVATE 1

3

Write Rsp Returned For PREPARE 1

4

Reserved

0

5

ReadyForDwnld Delay Secs

300

6

Activation Delay Secs

60

410 DOMAIN_

DESCRIPTOR

0

R/W Read/write-permitted

only for sub-index 1

1

Command

3

2

State

1

3

Error Code

0

4

Download Domain Index

440

5

Download Domain Header Index

420

6

Activated Domain Header Index

430

7

Domain Name

(Device name)

420 DOWNLOAD_

DOMAIN_

HEADER.1

0

1

Header Version Number

0

2

Header Size

0

3

Manufacturer ID

4

Device Family

5

Device Type

6

Device Revision

0

7

DD Revision

0

8

Software Revision

9

Software Name

10

Domain Name

430 DOWNLOAD_

DOMAIN_

HEADER.2

0

1

Header Version Number

1

2

Header Size

44

3

Manufacturer ID

0x594543

4

Device Family

(DEV_TYPE of RB)

5

Device Type

(DEV_TYPE of RB)

6

Device Revision

(DEV_REV of RB)

7

DD Revision

(DD_REV of RB)

8

Software Revision

(SOFT_REV of RB)

9

Software Name

ORIGINAL

10

Domain Name

(Device name)

440 DOMAIN

Read/write: prohibited

Get-OD: permitted