3 atex certification, Atex certification -8, Warning – Yokogawa EJX930A User Manual

Page 19

Advertising
background image

<2. Handling Cautions>

2-8

IM 01C25T02-01E

2.1.3 ATEX Certification

(1) Technical Data

a. ATEX Intrinsically Safe Ex ia
Caution for ATEX Intrinsically safe type.
Note 1. EJX/EJA-E series pressure transmitters

with optional code /KS26 for potentially

explosive atmospheres:

• No. KEMA 04ATEX1116 X

• Applicable Standard: EN 60079-0:2009,

EN 60079-11:2007/EN 60079-11:2012,

EN 60079-26:2007, EN 60079-27:2008,

EN 61241-11:2006

Note 2. Ratings

Type of Protection and Marking Code:

Ex ia IIC/IIB T4 Ga

Ex ia IIIC T85°C T100°C T120°C Db

Group: II

Category: 1G, 2D

Ambient Temperature for EPL Ga: –40 to 60°C

Ambient Temperature for EPL Db: –30* to 60°C

* –15°C when /HE is specified.

Maximum Process Temperature (Tp.): 120°C

Maximum Surface Temperature for EPL Db.

T85°C (Tp.: 80°C)

T100°C (Tp.: 100°C)

T120°C (Tp.: 120°C)

Ambient Humidity:

0 to 100% (No condensation)

Degree of Protection of the Enclosure:

IP66 / IP67

Electrical Data

• When combined with Trapezoidal and

Rectangular output characteristic FISCO

model IIC barrier

Ui = 17.5 V, Ii = 380 mA, Pi = 5.32 W,

Ci = 3.52 nF, Li = 0 μH

• When combined with Linear characteristic

barrier

Ui = 24 V, Ii = 250 mA, Pi = 1.2 W,

Ci = 3.52 nF, Li = 0 μH

• When combined with Trapezoidal or

Rectangular output characteristic FISCO

model IIB barrier

Ui = 17.5 V, Ii = 460 mA, Pi = 5.32 W,

Ci = 3.52 nF, Li = 0 μH

Note 3. Installation

• All wiring shall comply with local installation

requirements. (Refer to the installation

diagram)

Note 4. Maintenance and Repair

• The instrument modification or parts

replacement by other than authorized

representative of Yokogawa Electric

Corporation is prohibited and will void

DEKRA Intrinsically safe Certification.

Note 5. Special Conditions for Safe Use

WARNING

• In the case where the enclosure of the

Pressure Transmitter is made of aluminium,

if it is mounted in an area where the use of

category 1 G apparatus is required, it must

be installed such, that even in the event of

rare incidents, ignition sources due to impact

and friction sparks are excluded.

• Electrostatic charge may cause an explosion

hazard. Avoid any actions that cause the

generation of electrostatic charge, such as

rubbing with a dry cloth on coating face of

the product.

• In the case where the enclosure of the

Pressure Transmitter is made of aluminum,

if it is mounted in an area where the use of

category 2D apparatus is required, it shall

be installed in such a way that the risk from

electrostatic discharges and propagating

brush discharges caused by rapid flow of

dust is avoided.

• To satisfy IP66 or IP67, apply waterproof

glands to the electrical connection port.

• When the lightning protector option is

specified, the apparatus is not capable

of withstanding the 500V insulation test

required by EN60079-11.

This must be taken into account when

installing the apparatus.