4 iecex certification, Iecex certification -12 – Yokogawa EJX930A User Manual

Page 23

Advertising
background image

<2. Handling Cautions>

2-12

IM 01C25T02-01E

2.1.4 IECEx Certification

a. IECEx Flameproof Type
Caution for IECEx flameproof type.
Note 1. The transmitters with optional code /SF2

are applicable for use in hazardous

locations:

• No. IECEx CSA 07.0008

• Applicable Standard:

IEC60079-0:2004, IEC60079-1:2003

• Flameproof for Zone 1, Ex d IIC T6...T4

• Enclosure: IP66 and IP67

• Maximum Process Temperature:

120°C (T4), 100°C (T5), 85°C (T6)

• Ambient Temperature:

–50* to 75°C (T4), –50* to 80°C (T5),

–50* to 75°C (T6)

* –15°C when /HE is specified.

• Supply Voltage: 32 V dc max.

• Output Signal: 15 mA dc

Note 2. Wiring

• In hazardous locations, the cable entry

devices shall be of a certified flameproof

type, suitable for the conditions of use and

correctly installed.

• Unused apertures shall be closed with

suitable flameproof certified blanking

elements.

Note 3. Operation

• WARNING:

AFTER DE-ENERGIZING, DELAY 5

MINUTES BEFORE OPENING.

• WARNING:

WHEN AMBIENT TEMPERATURE ≥ 65°C,

USE THE HEAT-RESISTING CABLES ≥

90°C.

• Take care not to generate mechanical

sparking when accessing to the instrument

and peripheral devices in a hazardous

location.

Note 4. Maintenance and Repair

• The instrument modification or parts

replacement by other than authorized

representative of Yokogawa Electric

Corporation is prohibited and will void IECEx

Certification.

b. IECEx Intrinsically Safe Type / type n
Caution for IECEx Intrinsically safe and type n.
Note 1. The transmitters with optional code /SS25

are applicable for use in hazardous

locations

• No. IECEx CSA 05.0012

• Applicable Standard:

IEC 60079-0:2000, IEC 60079-11:1999,

IEC 60079-15:2001

• Ex ia IIC/IIB T4, Ex nL IIC T4

• Ambient Temperature: –40* to 60°C

* –15°C when /HE is specified.

• Max. Process Temp.: 120°C

• Enclosure: IP66 and IP67

Note 2. Entity Parameters

• Intrinsically safe ratings are as follows:

[Entity]

Maximum Input Voltage (Vmax/Ui) = 24 V

Maximum Input Current (Imax/Ii) = 250 mA

Maximum Input Power (Pmax/Pi) = 1.2 W

Maximum Internal Capacitance (Ci)

= 1.76 nF

Maximum Internal Inductance (Li) = 0 µH

[FISCO IIC]

Maximum Input Voltage (Vmax/Ui) = 17.5 V

Maximum Input Current (Imax/Ii) = 380 mA

Maximum Input Power (Pmax/Pi) = 5.32 W

Maximum Internal Capacitance (Ci)

= 1.76 nF

Maximum Internal Inductance (Li) = 0 µH

[FISCO IIB]

Maximum Input Voltage (Vmax/Ui) = 17.5 V

Maximum Input Current (Imax/Ii) = 460 mA

Maximum Input Power (Pmax/Pi) = 5.32 W

Maximum Internal Capacitance (Ci)

= 1.76 nF

Maximum Internal Inductance (Li) = 0 µH

• Type "n" ratings are as follows:

Maximum Input Voltage (Vmax/Ui) = 32 V

Maximum Internal Capacitance (Ci)

= 1.76 nF

Maximum Internal Inductance (Li) = 0 µH

• Installation Requirements

Uo ≤ Ui, Io ≤ Ii, Po ≤ Pi,

Co ≥ Ci + Ccable, Lo ≥ Li + Lcable

Voc ≤ Vmax, Isc ≤ Imax,

Ca ≥ Ci + Ccable, La ≥ Li + Lcable

Uo, Io, Po, Co, Lo, Voc, Isc, Ca and La are

parameters of barrier.