<9. Parameter Lists>

9-9

IM 01C25T02-01E

Relative

Index Index

Parameter Name

Factory Default Write

Mode

Explanation

20

2520

EXP_MODE1

0

O/S

Selection of the displayed value in exponent such as x1, x10,

x100, and x1000.

21

2521

BLOCK_TAG2

2014 (PRIMARY_

VALUE)

Block tag which includes a parameter to be displayed on

display2

22

2522

PARAMETER_SEL2

0 (PRIMARY_

VALUE)

O/S

Selection of a parameter to be displayed on display2. Select a

parameter from Table 6.1

23

2523

DISPLAY_TAG2

Null

O/S

Name of block tag to be displayed on display2; up to six

alphanumeric plus a slash [/] and a period [.]

24

2524

UNIT_SEL2

0 (Auto)

O/S

Selection of unit to be displayed. The unit of the parameter

which is selected at PARAMETER SEL2 will be displayed

when "Auto" is selected; user-specified unit at DISPLAY UNIT2

will be displayed when "Custom" is selected.

25

2525

DISPLAY_UNIT2

Null

O/S

User specified unit to be displayed on display2, which will be

available when "Custom" is selected at UNIT SEL2.

26

2526

EXP_MODE2

0

O/S

Selection of the displayed value in exponent such as x1, x10,

x100, and x1000.

27

2527

BLOCK_TAG3

2029

(SECONDARY_

VALUE)

Block tag which includes a parameter to be displayed on

display3

28

2528

PARAMETER_SEL3

1 (SECONDARY_

VALUE)

O/S

Selection of a parameter to be displayed on display3. Select a

parameter from Table 6.1

29

2529

DISPLAY_TAG3

Null

O/S

Name of block tag to be displayed on display3; up to six

alphanumeric plus a slash [/] and a period [.]

30

2530

UNIT_SEL3

0 (Auto)

O/S

Selection of unit to be displayed. The unit of the parameter

which is selected at PARAMETER SEL3 will be displayed

when "Auto" is selected; user-specified unit at DISPLAY UNIT3

will be displayed when "Custom" is selected.

31

2531

DISPLAY_UNIT3

Null

O/S

User specified unit to be displayed on display3, which will be

available when "Custom" is selected at UNIT SEL3.

32

2532

EXP_MODE3

0

O/S

Selection of the displayed value in exponent such as x1, x10,

x100, and x1000.

33

2533

BLOCK_TAG4

2047 (CAP_

TEMP_VAL)

Block tag which includes a parameter to be displayed on

display4

34

2034

PARAMETER_SEL4

3 (CAP_TEMP_

VAL)

O/S

Selection of a parameter to be displayed on display4. Select a

parameter from Table 6.1

35

2535

DISPLAY_TAG4

Null

O/S

Name of block tag to be displayed on display4; up to six

alphanumeric plus a slash [/] and a period [.]

36

2536

UNIT_SEL4

0 (Auto)

O/S

Selection of unit to be displayed. The unit of the parameter

which is selected at PARAMETER SEL4 will be displayed

when "Auto" is selected; user-specified unit at DISPLAY UNIT4

will be displayed when "Custom" is selected.

37

2537

DISPLAY_UNIT4

Null

O/S

User specified unit to be displayed on display4, which will be

available when "Custom" is selected at UNIT SEL4.

38

2038

EXP_MODE4

0

O/S

Selection of the displayed value in exponent such as x1, x10,

x100, and x1000.

39

2039

BAR_GRAPH_

SELECT

1 (display)

O/S

Selection of bar graph indicator

40

2540

DISPLAY_CYCLE

7 (2.8 s)

O/S

Duration of display cycle. (Time unit: 1=400 ms)

41

2541

POWER_ON_INFO

1

Display when powering on.

42

2542

TEST 40

0

O/S

Not used for the transmitter.

9.4 Al Function Block

Relative

Index

Index

AI1

Index

AI2

Index

AI3 Parameter Name Factory Default

Write

Mode

Explanation

0

4000

4100

4200

Block Header

TAG: “AI1” or

“AI2” or

“AI3”

Block

Tag =

O/S

Information on this block such as Block Tag, DD

Revision, Execution Time etc.

1

4001

4101

4201

ST_REV

The revision level of the static data associated

with the function block. The revision value will be

incremented each time a static parameter value in

the block is changed.

2

4002

4102

4202

TAG_DESC

Null

AUTO The user description of the intended application

of the block.