10.2 Optional Specifications

For items other than those described below, refer to each User’s Manual.

Item

Description

Code

Data configuration at factory

Software damping

CC

Software Download Function

Based on F

OUNDATION

fieldbus Specification (FF-883)

Download class: Class1

EE

Advanced diagnostics *

3

Multi-sensing process monitoring

• Impulse line blockage detection *

1

• Heat trace monitoring *

2

DG1

*1: The change of pressure fluctuation is monitored and then detects the impulse line blockage. See TI 01C25A31-01E for detailed

technical information required for using this function.

*2: Not applicable for flange mounted differential pressure transmitters and diaphragm sealed differential pressure transmitters

*3: Applicable for EJX series. This option code must be specified with option code EE.

10.3 Optional Specifications (For Explosion Protected type)

Item

Description

Code

Factory Mutual (FM)

FM Explosionproof *

1

FF1

FM Intrinsically safe and Nonincendive *

1

FS15

ATEX

ATEX Flameproof *

1

KF22

ATEX Intrinsically safe Ex ia *

1

KS26

ATEX Intrinsically safe Ex ic *

1

KN26

Canadian Standards

Association (CSA)

CSA Explosionproof *

1

CF1

CSA Intrinsically safe *

1

CS15

IECEx Scheme

IECEx Flameproof *

1

SF2

IECEx Intrinsically safe and type n *

1

SS25

Contact Yokogawa representative for the codes indicated as ‘-’.

*1: Applicable for Electrical connection code 2, 4, 7, 9, C and D .

< Factory Setting >

Tag Number (Tag plate)

As specified in order

Software Tag (PD_TAG)

‘PT2001’ unless otherwise both Tag Number and Software Tag

specified in order

Node Address

‘0xF5’ unless otherwise specified in order

Operation Functional Class

‘BASIC’ or as specified

Primary value *

1

Output Mode (L_TYPE)

‘Direct’ unless otherwise specified in order

Calibration Range (XD_SCALE)

Lower/Higher Range Value

As specified in order

Calibration Range Unit

Selected from mmH

2

O, mmH

2

O(68°F), mmHg, Pa, hPa, kPa,

MPa, mbar, bar, gf/cm

2

, kgf/cm

2

, inH

2

O, inH

2

O(68°F), inHg,

ftH

2

O, ftH

2

O(68°F) or psi. (Only one unit can be specified)

Output Scale (OUT_SCALE)

Lower/Higher Range Value

‘0 to 100%’ unless otherwise specified.

Software Damping *

2

‘2 seconds’ or as specified in order

Static pressur display range

‘0 to 25 MPa’ for M and H capsule and ‘0 to 16 MPa’ for L

capsule, absolute value. Measuring high pressure side.

*1: Primary means differential pressure in case of differential pressure transmitters and pressure in case of pressure transmitters.

*2: To specify this item, /CC option is required.