<3. INSTALLATION>

3-5

IM 01E25D11-01EN

(2) Carrying Flowtube

F0309.ai

90 degrees or less

90 degrees or less

Eye bolt

Eye plate

Figure 3.3.1 Carrying Flowtube

CAUTION

• When carrying the flowtube, use the lifting

rings (eye bolts or eye plates).

• To assure safety, keep lifting angle less than

90 degrees as shown in Figure 3.3.1

(3) Positioning Flowtube
Bring in the flowtube, place it and use a jack to

adjust its position.

IMPORTANT

Apply the jack to the flanges of the flowtube.

In addition, adjust any misalignment when the

flowtube is brought in, as the jack can adjust

vertical position, but not horizontal one.

(4) Applying Gasket and optional Grounding

Rings
Gasket:

Necessary gaskets for piping connection are

as below depending on the choice of grounding

rings.

Use sheet gaskets designed to fit for flange

standard. The GF type-1 gaskets by JIS G

3443-2 should be used for the JIS F12 flange

models in sizes 1100 mm (44 in.) and above. In

this case, the gasket groove is required on the

customer pipe flanges.

The thickness of gasket should be 2mm

(0.08in.) to 5mm (0.2in.) for sizes up to 1000

mm (40 in.), and 5 mm (0.2 in.) or more

for larger sizes. The type of gasket should

be a kind of soft rubber, or its equivalent in

hardness.

1. Standard (no grounding rings)

Gaskets A supplied by customer

Customer

pipe

Customer

pipe

A

A

F0310.ai

Figure 3.3.2 Installation without Grounding

Rings

When using the GF type-1 gaskets, the

gasket groove is required as mentioned

above.

2. With optional grounding rings (code GR1)

Optional grounding rings

Gaskets A and B supplied by customer

Customer

pipe

Customer

pipe

A

B

B

A

F0311.ai

Figure 3.3.3 Installation with Grounding Rings

GR1

It is recommended to use the same gasket

for A and B. Both gaskets A and B are to be

supplied by customer.

When polyurethane or natural soft rubber

lining, the gaskets B are not necessary.

3. With optional grounding rings (code GR2)

Customer

pipe

Optional grounding rings

with integrated gaskets B included

Gaskets A supplied by customer

Customer

pipe

F0312.ai

A

A

B

B

Figure 3.3.4 Installation with Grounding Rings

GR2

This is available for the models with

process connection JIS F12 (JIS 75M) in

sizes 1100 mm (44 in.) and above. Only

gaskets A are to be supplied by customer.

The grounding rings are installed and

locked onto the flowtube with gaskets B

when shipped from factory.

Mounting Procedure (no Grounding Rings):

Connect the flowtube’s flange and the

customer’s pipe which contact process fluid by

some wire supplied by customer.

Advertising