<5. MAINTENANCE>

5-1

IM 01E25D11-01EN

5. MAINTENANCE

WARNING

• Maintenance work must be carried out by the

trained personnel having knowledge of safety

standard and not by operators.

• When opening the cover, wait for more

than 10 minutes after turning off the power.

Furthermore, opening of the cover must also

be carried out by the trained personnel having

knowledge of safety standard.

CAUTION

• When opening the cover, use a hexagonal

wrench (nominal size 3 mm).

• Be sure to lock the cover using a hexagonal

wrench (nominal size 3 mm) after installing the

cover.

5.1 Changing Direction of

Electrical Connection

IMPORTANT

The following types can not be changed direction

of electrical connection after delivery.

• Submersible Type.

• Optional code DHC (for district heating and

cooling or condensation-proof).

(1) The following tools are required to change the

direction of the electrical connection:

• Hexagonal wrench (nominal size 1.5 mm)

• Wrench

(2) Turn off the power to the flowmeter.

(3) Using the wrench, loosen the hexagonal nut at

the neck of the instrument.

F0501.ai

(4) Using the hexagonal wrench, loosen the screw

in the neck.

(5) Turn the terminal box in the desired direction.

NOTE

The terminal box can be turned –140 degree to

+180 degree from the arrow mark indicating the

flow direction. Do not exceed these angle.

(6) Using the hexagonal wrench, retighten the neck

screw.

F0502.ai

+180º

-140º

(7) Using the wrench, retighten the hexagonal nut

at the neck. After that, check that the terminal

box is fixed.