<6. OUTLINE>

6-4

IM 01E25D11-01EN

For Process Connection JIS F12 (JIS 75M)

Model

Suffix Code

Description

Available Size / Model

AXW500

Size 500 mm (20 in.) Remote Flowtube

AXW600

Size 600 mm (24 in.) Remote Flowtube

AXW700

Size 700 mm (28 in.) Remote Flowtube

AXW800

Size 800 mm (32 in.) Remote Flowtube

AXW900

Size 900 mm (36 in.) Remote Flowtube

AXW10L

Size 1000 mm (40 in.) Remote Flowtube

AXW11L

Size 1100 mm (44 in.) Remote Flowtube

AXW12L

Size 1200 mm (48 in.) Remote Flowtube

AXW13L

Size 1350 mm (54 in.) Remote Flowtube

AXW15L

Size 1500 mm (60 in.) Remote Flowtube

AXW16L

Size 1600 mm (64 in.) Remote Flowtube

AXW18L

Size 1800 mm (72 in.) Remote Flowtube

Use

G

General-purpose type

W

Submersible type

Converter

-N

Remote Flowtube for Combined Use with

AXFA11

Power Supply

N

Remote Flowtube

Lining (*1)

U

Polyurethane Rubber

Electrode Material (*1)

L

JIS SUS316L (AISI 316L SS Equivalent)

H

Hastelloy C276 Equivalent

Electrode Structure

1

Non-replaceable

Grounding Structure (*2)

N

None (*3), available as optional feature

(GR1 or GR2)

Process Connection

-CG1

JIS F12 (JIS 75M) Flange (Carbon Steel)

Lay Length

N

Standard

Electrical Connection

-0

JIS G1/2 female

-2

ANSI 1/2 NPT female

Not available for Submersible type

-4

ISO M20 x 1.5 female

Not available for Submersible type

Indicator

N

None

Calibration

B

Standard

Optional Specifications

/

Optional code

*1:

Users must consider the characteristics of selected wetted parts material and influence of process fluids. The use of inappropriate materials

can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the

instrument itself can be damaged and that fragments from the instrument can contaminate the user’s process fluids.

Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-

temperature steam (150°C [302°F] or above). Contact Yokogawa for detailed information of the wetted parts material.

*2: Select optional grounding rings (code GR1 or GR2) if necessary. For example, grounding rings are necessary for plastic piping.

The code GR1 is optional only for sizes 500 mm (20 in.) to 1000 mm (40 in.).

The code GR2 is optional only for sizes 1100 mm (44 in.) to 1800 mm (72 in.).

*3: “None” is applicable only for metal piping and wiring for grounding will be necessary so that the electric potentials between flowtube and piping