5 wiring ports, Wiring ports -17, Important – Yokogawa ADMAG CA User Manual

Page 26

Advertising
background image

4.INSTALLATION

IM 1E8B0-01E

4-17

4.4.5 Wiring Ports

Please select the most suitable standard of wiring procedure for the wiring ports by
customer’s own.

This instrument is of watertight construction as stipulated in JIS C0920 (Tests to prove
protection against ingress of water and degrees of protection against ingress of solid
objects for electrical equipment.) It is shipped with a wiring bracket (waterproof gland
or waterproof gland with union) or a plastic gland attached, only in cases where an
optional specification is selected for the wiring port.

In case of the explosion proof type, refer to chapter 13.

The wiring port is sealed with a cap (not water-proof). Do not remove the
cap from the unused wiring port. If waterproof property is necessary, please
use waterproof glands.

(1) When waterproof property is unnecessary

(When there are no particular optional specifications)

The wiring port is sealed with a cap (not water-proof) that must be removed before
wiring. At this time, handle the wiring port in accordance with the JIS C0920 men-
tioned above. Do not remove the cap from the unused wiring port.

(2) When waterproof property is necessary

(Wiring using waterproof glands)

To prevent water or condensate from entering the converter housing, water
proof glands are recommended. Do not over-tighten the glands or damage
to the cables may result. Tighteness of the gland can be checked by
confirming that the cable is held firmly in place.

Waterproof gland
Optional specification
code: / ECG

Waterproof gland with union
joint Optional specification
code: / ECU

Gasket

Tightening gland

Tightening gland

G 1/2

Gasket

G 1/2
(PF 1/2 internal thread)

Figure 4.4.2

Waterproof Gland

IMPORTANT

IMPORTANT

Advertising