Yokogawa Wireless Temperature Transmitter YTA510 User Manual

Page 29

Advertising
background image

IM 01C50T03-01E

5-3

5. LIST OF PARAMETERS

J

CAL SENSOR1

Sensor1 sensor trim

R

J05

SNSR1 CLR

Sensor1 trim value clear

W

USER CAL ACT, USER CAL IGNORE,
USER CAL CLEAR

J07

IN TRIM MODE

Input Sensor Trimming Mode

W

V.R/ZERO&GAIN, V.R/ZERO,
TEMP/ZERO&GAIN, TEMP/ZERO

J10

SNSR1 ZERO

Sensor1 zero point adjustment

W

J20

SNSR1 GAIN

Sensor1 gain point adjustment

W

J30

SNSR1 SERIAL

Sensor1 serial number

W

000000 to 999999

J60

SELF CHECK

Self-diagnostics

R

Same as A60

K

CAL SENSOR2

Sensor2 sensor trim

R

K05 SNSR2 CLR

Sensor2 trim value clear

W

USER CAL ACT, USER CAL IGNORE,
USER CAL CLEAR

K10 SNSR2 ZERO

Sensor2 zero point adjustment

W

K20 SNSR2 GAIN

Sensor2 gain point adjustment

W

K30 SNSR2 SERIAL

Sensor2 serial number

W

000000 to 999999

K60

SELF CHECK

Self-diagnostics

R

Same as A60

L

CAL OUTPUT

Analog output trim

R

L05

OUT CLR

Output trim value clear

W

USER CAL ACT, USER CAL IGNORE,
USER CAL CLEAR

L10

OUTPUT MODE Output mode

W

AUTOMATIC MODE, MANUAL MODE 4mA,
MANUAL MODE 20mA

L20

OUT ZERO

Output zero point adjustment

W

0.6V to 1.4V

L30

OUT GAIN

Output gain point adjustment

W

4.6V to 5.4V

L60

SELF CHECK

Self-diagnostics

R

Same as A60

M

SET METER

Set Meter

R

M10 PROCESS DISP Process variable display

W

PV, SV, TV, 4V, PV-SV, PV-SV-TV,

PV-SV-TV-4V, INHIBIT

M20 %/mA DISP

Output in % / mA display

W

mA, %, mA-%, INHIBIT

M30 MATRIX DISP

Dot matrix display

W

PROCESS, TYPE, WIRE, PROCESS-TYPE,

TYPE-WIRE, INHIBIT

M40 BAR GRAPH

Output bar graph display

W

SHOW, INHIBIT

M50 DISP UPDATE

Display update speed

W

FAST, NORMAL, SLOW

M55 Err-NO DISP

Error number display

W

SHOW, INHIBIT

M60 SELF CHECK

Self-diagnostics

R

Same as A60

O MEMO

Memo

R

O10

MEMO1

Memo 1

W

16 alphanumeric characters

O20

MEMO2

Memo 2

W

16 alphanumeric characters

O30

DESCRIPTOR

Description

W

16 alphanumeric characters

O40

DATE

Date

W

6 alphanumeric characters

O60

SELF CHECK

Self-diagnostics

R

Same as A60

P RECORDS Records

R

P05

LOG CLEAR

Log clear

R

DISABLE, ENABLE

P10

PV MIN LOG

PV minimum log

R

P11

PV MAX LOG

PV maximum log

R

P12

SV MIN LOG

SV minimum log

R

P13

SV MAX LOG

SV maximum log

R

P14

TV MIN LOG

TV minimum log

R

P15

TV MAX LOG

TV maximum log

R

P16

4V MIN LOG

4V minimum log

R

P17

4V MAX LOG

4V maximum log

R

P18

TERM MIN LOG Terminal minimum log

R

P19

TERM MAX LOG

Terminal maximum log

R

P20

ERR LOG1

Error log 1

R

Error message display

P21

ERR LOG2

Error log 2

R

Error message display

P22

ERR LOG3

Error log 3

R

Error message display

P23

ERR LOG4

Error log 4

R

Error message display

P24

ERR LOG CLR

Error log clear

W

DISABLE, ENABLE

P30

OPERATE TIME Transmitter operation time (after

R

instantaneous interrupt detection

operation starts)

P31

POWER CHECK Instantaneous interrupt detection

W

STOP, START

history & detection start

P40

BCC ERROR % BRAIN communication BCC error

R

generation rate

P60

SELF CHECK

Self-diagnosis

R

Same as A60

USER CAL ACT

V.R/ZERO&GAIN

0

0

0

GOOD

USER CAL ACT

0

0

0

GOOD

USER CAL ACT

AUTOMATIC MODE

0

0

GOOD

PV

mA

PROCESS

SHOW

NORMAL

SHOW

GOOD

(Blank)

(Blank)

(Blank)

(Blank)

GOOD

DISABLE

Operation

Operation

Operation

Operation

Operation

Operation

Operation

Operation

15

°

C

35

°

C

GOOD

GOOD

GOOD

GOOD

DISABLE

Operation

STOP

0 %

GOOD

NO.

Parameter name

Content

R/W

Remarks

Applicable model

UPLOAD DATA

110 310 320 SET ALL

Data initial value

YTA110 YTA310 YTA320

*1

*2

*3

*

1:

indicates parameters which may be displayed depending on the setting for other parameters.

*

2: RW: R = Read only, W = Read & Write

*

3: Indicates the parameter selected by H30: UPLOAD SELCT.

SET = SET PRAM ONLY parameters

ALL = ALL PRAM parameters

*

4: degF and degR can be selected only when optional code /D2 is specified.

*

5: This parameter will not be printed at PRINTOUT upon UPLOAD/DOWNLOAD, although the parameter itself is UPLOADED/DOWNLOADED.

*5

*5

*5

Advertising
This manual is related to the following products: