Yokogawa µR10000 User Manual

Page 53

Advertising
background image

53

IM 04P01B01-02E

Setup Items in Basic Setting Mode and Their Default Values

(Recorder version: 1.31)

Setup Item

Pen/Dot

Selectable Range or Selections

Default Value

Alarm > Diagnosis

-

On/Off

Off

Alarm > Reflash

-

On/Off

Off

Alarm > AND

-

None/I01/I01-I02/I01-I03/I01-I04/I01-I05/I01-I06 None

Alarm > Act

-

Energize/De_energize

Energize

Alarm > Behavior

-

Nonhold/Hold

Nonhold

Alarm > Indicator

-

Nonhold/Hold

Nonhold

Alarm > Increase

-

01 to 15

01

Alarm > Decrease

-

01 to 15

01

Alarm > Hysteresis

-

Off/0.1% to 1.0%

0.5%

Alarm > M_Hysteresis

-

Off/0.1% to 1.0%

Off

A/D > Integrate

Dot Model Auto/50Hz/60Hz/100ms

Auto

Pen Model Auto/50Hz/60Hz

Auto

Burnout > CH

-

01 to 06

01

Burnout > Burnout

-

Off/Up/Down

Off

RJC > CH

-

01 to 06

01

RJC > RJC

-

Internal/External

Internal

RJC > RJC > Volt

-

–20000 to 20000 µV

0 µV

Color > Channel

Dot Model 01 to 06

01

Color > Color

Dot Model Purple/Red/Green/Blue/Brown/Black

01: Purple, 02: Red,
03: Green, 04: Blue,
05: Brown, 06: Black

POC > POC

Pen Model On/Off

Off

Print > CH/Tag

-

CH/Tag

CH

Print > Channel

Dot Model On/Off

On

Print > Alarm

-

On1/On2/Off

On1

Print > Record On

-

On/Off

Off

Print > Chart speed

-

On/Off

On

Print > Scale

-

On/Off

On

Print > Pen color

Pen Model On/Off

On

Print1 > Periodic

-

Auto/Manual

Auto

Print1 > Ref. Time

-

Hour 0 to 23 (1 hour steps)

00:00

Print1 > Interval

-

10min/15min/20min/30min/1h/2h/3h/4h/6h/8h/

12h/24h

1h

Print1 > Mode

-

Inst/Report/Off

Inst

Print2 > CH

-

01 to 06

01

Print2 > Mode

-

AVE/MIX/SUM/MIN/MAX/INST

AVE

Print2 > SUM scale

-

Off, /s, /min, /h, /day

Off

Bar graph > CH

-

01 to 06

01

Bar graph > Graph

-

Normal/Center

Normal

Keylock > Keylock

-

Not/Use

Not

Keylock > Password

-

Numbers and spaces within 4 digits

Blank

Keylock > RCD

-

Free/Lock

Free

Keylock > Feed

-

Free/Lock

Free

Keylock > Menu

-

Free/Lock

Free

Keylock > Disp Menu

-

Free/Lock

Free

Keylock > Alarm ACK

-

Free/Lock

Free

Keylock > Math

-

Free/Lock

Free

Keylock > Print out

-

Free/Lock

Free

Keylock > Message

-

Free/Lock

Free

Keylock > Buffer clear

-

Free/Lock

Free

Keylock > Periodic

-

Free/Lock

Free

Keylock > Pen exchange

Pen Model Free/Lock

Free

Keylock > R. exchange

Dot Model Free/Lock

Free

Moving_AVE > Moving_AVE

Dot Model Not/Use

Not

Filter > Filter

Pen Model Not/Use

Not

Partial > Partial

-

Not/Use

Not

Language > Lang

-

English/Japanese/German/French

English

Date format > Type

-

Y/M/D M/D/Y D/M/Y D.M.Y M.D.Y

M.D.Y

Temperature > Temp

-

°C/°F

°C

Setup Items and Default Values

Advertising