Recorder’s Version and Functions Described in This Manual

The contents of this manual corresponds to the recorder with version 1.31.

µR10000 Versions and Functions

Version

Suffix Code Added or Modified Functions

Reference

1.02 or earlier

1.11

(Added)

The printout/display format of the date can be changed.

Sec. 7.19 in the User’s Manual

(IM 04P01B01-01E)

(Added)

Key operation to move the printer carriage near the center position so that the

ribbon cassette can be replaced with the recorder turned ON (dot model)

Sec. 3.4 in the User’s Manual

(IM 04P01B01-01E)

(Changed) Selectable range of alarm values during linear scaling (including 1-5V and

SQRT) to -5% to 105% of the scale span.

Sec. 5.2 in the User’s Manual

(IM 04P01B01-01E)

(Changed) The procedure to set the start/end date and time of Daylight Saving Time (DST)

has been changed.

Sec. 6.16 in the User’s Manual

(IM 04P01B01-01E)

/C3

(Added)

Modbus/RTU slave protocol, two-wire system

Communication manual

/C7

(Changed) Users with the same user name cannot be registered.

Communication manual

1.21

-2

(Added)

Language support (German and French)

Sec. 1.9 in the User’s Manual

(IM 04P01B01-01E)

/CC1

(Added)

Calibration Correction

Sec. 1.2 in the User’s Manual

(IM 04P01B01-01E)

/H5x

(Added)

Portable type

Page 19 and 14 in this manual

/P1

(Added)

24 VDC/AC power supply operation

Page 19 and 20 in this manual

1.31

(Added)

Customized menu

Sec. 1.9 in the User’s Manual

(IM 04P01B01-01E)

(Added)

Modbus register (40301 to 40348)

Communication manual

/BT1

(Added)

Header printout

Sec. 1.4 in the User’s Manual

(IM 04P01B01-01E)

• Checking the Version Number
You can check the version number on the System display.
The System display cannot be shown at the factory default condition.
First, register the System display to the display screen.

• Procedure of registering the System display to the display screen: See Changing the Displayed Information on Page 46.
• Procedure of displaying the System display: The screen switches each time the

DISP key is pressed. Press the DISP key repeatedly until

System display is shown. The displayed contents on the System display switches every 3 seconds. Check the number shown by the “Version:”
item.

Software (Sold Separately)

The table below shows the relationship between the RXA10 Configuration Software revisions and the µR10000 recorder versions.

Recorder version

1.02 or earlier

1.11

1.21

1.31

RXA10 Configuration Soft-

ware revision

R1.01

Yes

Limited

R2.01

Yes

Yes

Yes

Limited

R3.01

Yes

Yes

Yes

Yes

Yes:

Compatible

Limited: The new functions of the recorder cannot be configured from the RXA10.