Yokogawa µR10000 User Manual

Page 54

Advertising
background image

54

IM 04P01B01-02E

Setup Item

Pen/Dot

Selectable Range or Selections

Default Value

Personalize > Add function > Bias

-

Not/Use

Not

Personalize > Add function >

SQRT low-cut

-

Not/Use

Use

Personalize > Add function > 1-5V low-cut

-

Not/Use

Not

Personalize > Add function > Alarm delay

-

Not/Use

Not

Personalize > Add function > Calibration

-

Not/Use

Use

Personalize > Time print > Alarm

-

HH:MM, HH:MM:SS, M/D H:M, M/D H:M:S,

YMD H:M:S

HH:MM

Personalize > Time print > Message

-

HH:MM, HH:MM:SS, M/D H:M, M/D H:M:S,

YMD H:M:S, None

HH:MM

Personalize > Time print > RCD On

-

HH:MM, HH:MM:SS, M/D H:M, M/D H:M:S,

YMD H:M:S

HH:MM

Personalize > Time print > C.Speed

-

HH:MM, HH:MM:SS, M/D H:M, M/D H:M:S,

YMD H:M:S

HH:MM

Setting initialization
Initialize > Mode

-

Setup+Set/Set

Setup+Set

Initialize > Mode > Are you sure?

-

No/Yes

No

Remote (/R1 option)
Remote > Remote No.

-

1/2/3/4/5

1

Remote > Remote No. > No.

-

Record On Off /Chart speed/Time adjust/

Math start stop (/M1)/Math reset (/M1)/

Manual print/Alarm ACK/Message1/Message2/

Message3/Message4/Message5/Priority

R_RCD (/BT1)/BatchCMT switch (/BT1)/None

(/M1, /BT1: option)

Record On/Off

Math (/M1 option)
Math > Timer (TLOG) > Timer No.

-

1/2

1

Math > Timer (TLOG) > Mode

-

Off/Relative/Absolute

Absolute

Math > Timer (TLOG) > Interval (Relative)

-

10 min to 24 h (1 min steps)

01:00

Math > Timer (TLOG) > Interval (Absolute)

-

10min/12min/15min/20min/30min/1h/2h/3h/4h/

6h/8h/12h/24h

1h

Math > Timer (TLOG) > Ref. Time

-

Hour 0 to 23 (1 hour steps)

00:00

Math > Timer (TLOG) > Reset

-

On/Off

On

Math > Timer (TLOG) > Print

-

On/Off

On

Math > Color > Channel

Dot Model 0A/0B/0C/0D/0E/0F/0G/0J/0K/0M/0N/0P

0A

Math > Color > Color

Dot Model Purple/Red/Green/Blue/Brown/Black

Purple: 0A/0G

Red: 0B/0J

Green: 0C/0K

Blue: 0D/0M

Brown: 0E/0N

Black: 0F/0P

Math > Output pen > Pen←CH

Pen Model Pen: 1 to 4, Channel: 01 to 04/0A to 0J

1pen: 01, 2pen: 02,

3pen: 03, 4pen: 04

Math > Print2 > CH

-

0A/0B/0C/0D/0E/0F/0G/0J/0K/0M/0N/0P

0A

Math > Print2 > Mode

-

AVE/MIX/SUM/MIN/MAX/INST

AVE

Math > Print2 > SUM scale

-

Off, /s, /min, /h, /day

Off

Math > Bar graph > CH

-

0A/0B/0C/0D/0E/0F/0G/0J/0K/0M/0N/0P

0A

Math > Bar graph > Graph

-

Normal/Center

Normal

Math > Error data > Error

-

+Over/–Over

+Over

Math > Error data > Over

-

Skip/Limit

Skip

RS-422/485 (/C3 option)
RS-422/485 > Address

-

1 to 32

1

RS-422/485 > Baud rate

-

1200/2400/4800/9600/19200/38400

9600

RS-422/485 > Data length

-

7/8

8

RS-422/485 > parity

-

Odd/Even/None

Even

RS-422/485 > Protocol

-

NORMAL/MODBUS

NORMAL

Ethernet (/C7 option)
Ethernet > Host > Host

-

64 characters or less

Blank

Ethernet > Host > Domain

-

64 characters or less

Blank

Ethernet > Local IP > A

-

IP address

0.0.0.0

Ethernet > Local IP > M

-

IP address (Subnet mask)

0.0.0.0

Ethernet > Local IP > G

-

IP address (Default gateway)

0.0.0.0

Ethernet > DNS > DNS

-

On/Off

Off

Ethernet > DNS > P

-

IP address (Primary DNS sever)

0.0.0.0

Setup Items and Default Values