Pointe Controller User Guide
Appendix A: OptiLogic Technical Specifications
267
Connection Diagram
Terminals
10
Out 2
Open collector output 2
9
Out 1
Open collector output 1
8
Common
Common for LS and two outputs
7
LS
Limit Switch input (optional)
6
Z2
5
Z1
Z input (optional)
4
B2
3
B1
Pulse input B (quadrature) /
Direction input (pulse & direction) /
Down pulse (up/down count)
2
A2
1
A1
Pulse input A (quadrature) /
Pulse input (pulse & direction) /
Up pulse (up/down count)
The OL2258 High Speed Pulse counter is designed to interface to a variety of
standard pulse encoder devices: differential, sourcing, or sinking. The figures
below illustrate connections for each type of encoder.