• VLAN 1 cannot be used as a classification CTAG.
• Ingress and egress tagging behavior is controlled by the interface-level configuration, not by the

global configuration.

The following summarizes the native service VF (VLAN ID > 4095) classifications that can or cannot
be supported with the respective commands.

Service VF native VLAN classifications

TABLE 64

Ingress allowed frame type

Egress
tagging:
Untagged
only

Egress
tagging:
Tagged only

CLI

None

N/A

N/A

None (tagged native VLAN is always
forwarded)

Untagged only

No

N/A

switchport trunk native vlan vid,

no switchport trunk tag native-vlan

Tagged only

N/A

Yes

switchport trunk native vlan vid ctag cvid,

switchport trunk tag native-vlan

Untagged and tagged

Yes

No

switchport trunk native vlan vid ctag cvid,

no switchport trunk tag native-vlan

The following illustrates configurations that are valid or invalid in regular trunk mode.

(config)# int te 5/0/1

(config-if-te-5/0/1)# switchport mode trunk

(config-if-te-5/0/1)# switchport trunk native-vlan-untagged 6000

ERROR: invalid command

# VLAN 1 cannot be used as a classification tag

(config-if-te-5/01)# switchport trunk native-vlan 6000 ctag 1

ERROR: default vlan 1 cannot be classified to a virtual fabric

# CTAG not used elsewhere can be used

(config-if-te-5/01)# switchport trunk native-vlan 6000 ctag 2

# Service VF classification without C-TAG is permitted if ingress frame type allows

untagged packet

# at that interface. Global mode tagging control does not apply to a service VF.

(config-if-te-5/01)# switchport trunk native-vlan 7000

ERROR: interface is not configured to accept untagged packet

(config-if-te-5/01)# no switchport trunk tag native-vlan

(config-if-te-5/01)# switchport trunk native-vlan 7000

No-default-native-VLAN trunk mode

Another set of native VLAN classifications for service and transport VFs is available in trunk mode
without the implicit creation of a default VLAN. The purpose of this trunk mode is to provide flexibility
that is not available in default VLAN trunk mode and do the following:

• Provide a raw Layer 2 switchport with no VLAN configuration.
• Allow native VLAN configuration when it is needed.
• Allow the mapping of a native VLAN to a service or transport VF.
• Allow the independent specification of ingress acceptable frame type and egress tagging options.

This trunk mode differs from the default-VLAN trunk mode in the following ways:

No-default-native-VLAN trunk mode