Managing the icx 6610 hardware, Managing temperature settings, Using the temperature sensor – Brocade ICX 6610 Stackable Switch Hardware Installation Guide User Manual

Page 77: Displaying the temperature

Advertising
background image

Managing the ICX 6610 Hardware

Managing temperature settings.......................................................................................75

Removing MAC address entries..................................................................................... 78

Displaying ICX 6610 CPU usage.................................................................................... 78

Hardware maintenance schedule....................................................................................79

Replacing a copper or fiber optic module........................................................................79

CAUTION

The procedures in this manual are for qualified service personnel.

Managing temperature settings

This section describes how to display temperature settings on the device and how to change the
temperature warning and shutdown levels.

Using the temperature sensor

The device contains temperature sensors that the software reads based on a configurable device poll
time. To protect the device from overheating, the following temperature threshold levels exist:

The warning level is the temperature at which the device generates a Syslog message and SNMP
trap. It is configurable.

The shutdown level is the temperature at which the device reboots. It is set by the device and is not
configurable.

The fan speed settings are set by the device, and are not configurable.

Displaying the temperature

To display the temperature of a device, enter the show chassis command at any level of the CLI.

NOTE
This temperature reflects the temperature of the board inside the device.

device#sh chassis

The stack unit 1 chassis info:

Power supply 1 not present

Power supply 2 (NA - AC - Regular) present, status ok

Power supply 2 Fan Air Flow Direction: Front to Back

Fan 1 ok, speed (auto): [[1]]<->2

Fan 2 not present

Fan controlled temperature: 53.5 deg-C

Fan speed switching temperature thresholds:

Speed 1: NM<----->80 deg-C

Speed 2: 75<-----> 85 deg-C (shutdown)

Fan 1 Air Flow Direction: Front to Back

Brocade ICX 6610 Stackable Switch Hardware Installation Guide

75

53-1003082-02

Advertising