Storage environment, Cooling system and fans – Brocade ICX 6610 Stackable Switch Hardware Installation Guide User Manual

Page 84

Advertising
background image

Operating environment

TABLE 16

Operating Temperature

Relative Humidity

Operating Altitude

0° - 40° C (32° - 104° F)

10 to 93%, @ 40° C (104°F), non-condensing

0 - 3000 meters (10,000 feet)

Storage environment

The following table provides the storage environment specifications.

Storage environment specifications

TABLE 17

Storage temperature

Storage humidity

Storage altitude

-25º C to 70º C (-13º F to 158° F)

95% maximum, non-condensing

4,500 meters (15,000 feet)

Cooling system and fans

The fans cool the CPU, main memory, and voltage regulators. For ICX 6610 switches, the fans use
either a push or pull configuration to move the air between the back and front of the device.

The first figure below shows the airflow for models with front to back airflow. The second figure below
shows the airflow for models with back to front airflow.

Storage environment

82

Brocade ICX 6610 Stackable Switch Hardware Installation Guide

53-1003082-02