4. Refer to the following redundancy member information:

IP Address

Displays the IP addresses of the members of the redundancy group. There are a
minimum of 2 members needed to define a redundancy group, including this
current module.

Status

Displays the current status of this group member. This status could have the
following values:

Configured - The member is configured on the current wireless service
module.

Seen - Heartbeats can be exchanged between the current switch and this
member.

Invalid - Critical redundancy configuration parameter(s) of the peer (heartbeat
time, discovery time, hold time, Redundancy ID, Redundancy Protocol version
of this member) do not match this switch’s parameters.

Not Seen - The member is no more seen by this switch.

Established - The member is fully established with this current module and
licensing information already been exchanged between this switch and the
member.

Adoption Count

Displays the number of Access Ports adopted by this member.

Adoption Capacity

Displays the maximum number of Access Ports this member is licensed to adopt.
For information on licensing rules impacting redundancy group members, see

“Redundancy group license aggregation rules”

on page 279.

Mode

The Redundancy Mode could be Active or Standby depending on the mode
configuration on the member. Refer to the Configuration screen to change the
mode

License Count

Displays the number of port licenses available for this switch. For information on
licensing rules impacting redundancy group members, see

“Redundancy group

license aggregation rules”

on page 279.

Image Version

Displays the image version currently running on this member. Is the selected
version complimentary with this switch’s version?

First Seen

Displays the time this member was first seen by the switch.

Last Seen

Displays the time this member was last seen by the switch.

HB Sent

Displays the number of heartbeats sent from the switch to this member since the
last reboot of the switch.

HB Received

Displays the number of heartbeats received by the switch since the last reboot.

Updates Sent

Displays the number of updates sent from the switch since the last reboot.
Updates include, authorization level, group authorization level and number of
Access Ports adopted.

Updates Received

Displays the number of updates received by the current switch from this member
since the last reboot.

Radio Portals

Displays the number of radio portals detected on each redundancy member listed.

Associated MUs

Display the number of MUs associated with each member listed.

Rogue APs

Displays the number of Rogue APs detected by each member. Use this information
to discern whether these radios represent legitimate threats to other members of
the redundancy group.

Self Healing Radios

Displays the number of self healing radios on each detected member. These radios
can be invaluable if other radios within the redundancy group were to experience
problems requiring healing by another radio.

Advertising