Mounting a Brocade Mobility 7131N-FGR Access Point
2
2. Tape the template to the wall mounting surface.
•
If the installation requires the antenna be positioned vertically, the centerline reference (of the
template) needs to be positioned vertically. The cabling shall exit the access point in a vertical
direction.
•
If the installation requires the antenna be positioned horizontally, the vertical centerline (of the
template) needs to be positioned horizontally. The cabling shall exit the access point in a
horizontal direction.
3. At mounting targets A and B, mark the mounting surface through the template at the target
center.
4. Discard the mounting template.
5. At each point, drill a hole in the wall, insert an anchor, screw into the anchor the wall mounting
screw and stop when there is 1mm between the screw head and the wall.
6. If pre-drilling a hole, the recommended hole size is 2.8mm (0.11in.) if the screws are going
directly into the wall and 6mm (0.23in.) if wall anchors are being used.
7. If required, install and attach a security cable to the access point’s lock port.
8. Attach the antennas to their correct connectors.
9. For more information on available antennas, see
10. Place the large center opening of each of the mount slots over the screw heads.
11. Slide the access point down along the mounting surface to hang the mount slots on the screw
heads.
CAUTION
Ensure you are placing the antennas on the correct connectors (depending on your dual-radio
model and frequency used) to ensure the successful operation of the access point.
NOTE
It is recommended the access point be mounted with the RJ45 cable connector oriented
upwards or downwards to ensure proper operation.
12. Cable the access point using an approved line cord and power supply.
For standard 48-Volt Power Adapter (Part No. 50-14000-247R) and line cord installations:
a. Connect RJ-45 CAT5e (or CAT6) Ethernet cable between the network data supply (host)
and the access point’s GE1/POE port.
b. Verify the power adapter is correctly rated according the country of operation.
c. Connect the power supply line cord to the power adapter.
d. Attach the power adapter cable into the power connector on the access point.
e. Plug the power adapter into an outlet.
13. Verify the behavior of the access point’s LEDs. For more information, see