1.) Select TERMINAL CONFIGURATION from the

MANAGEMENT FUNCTIONS menu.

2.) Select SET TERMINAL PARAMETERS.
3.) Select CASSETTE SETUP.
4.) Choose the MULTIPLE AMOUNT option.

D

ESCRIPTION

:

The MULTIPLE AMOUNT must be set in the Cash Dispenser before any transactions can be
processed. This number is the denomination of the currency installed in the currency cassette. It
can be set to 10, 20, 50, or 100.

Whenever a withdrawal transaction is performed, the amount entered or selected is compared to
the MULTIPLE AMOUNT. If the entry is not a even multiple of this amount, an error warns the
terminal user and displays the current multiple amount.

E

RROR

C

ONDITIONS

:

If the MULTIPLE AMOUNT is not set correctly, the terminal will respond by going into Configu-
ration Error 186, BILL SIZE NOT CONFIGURED CORRECTLY. To correct the error condition
enter the management functions and configure the bill size (MULTIPLE AMOUNT) to the size of
the bill in the cassette.