4 Configuration parameters

Language

Configuration
➔ Device data

➔ Language

German, English, French,
Dutch, Spanish, Italian,
Hungarian, Czech,
Swedish, Polish, Danish,
Finnish, Portuguese,
Russian

Temperature unit

Configuration
➔ Device data

➔ Temperature unit

°C, °F

Memory upload

Configuration
➔ Device data

➔ Memory upload

via CF card,
via RSxxx

You can determine how
data are mainly to be
uploaded. The value for the
available capacity (shown
in the status line) will vary
according to the selection.

Memory alarm

Configuration
➔ Device data

➔ Memory alarm

0 — 10 — 100%

The signals
“IntMemAlmCF”,
“IntMemAlmInterf” and
“MemAlmCFcard” are
activated when the residual
capacity of the internal
memory or the CF card has
fallen to this value. Chapter
2.4 “Digital signals (event
traces)”

Code number for
the configuration

Configuration
➔ Device data

➔ Code No. (password)

➔ Configuration

00000 — 09200 — 09999

Code number for
configuration level;
0000 = off
The data saved in the
FLASH memory will be
deleted when the
configuration is changed.

Code number:
CompactFlash
card menu
(CF code No.)

Configuration
➔ Device data

➔ Code No. (password)

➔ CF manager

00000 — 09200 — 09999

Code number for
menu functions
CompactFlash card;
0000 = off

Code number:
Reset counter/int.

Configuration
➔ Device data

➔ Code No. (password)

➔ Reset counter/int.

00000 — 09200 — 09999

Code number to delete
individual counts;
0000 = off

Code number:
RS232/RS485 +
Ethernet

Configuration
➔ Device data

➔ Code No. (password)

➔ RS232/RS485+

Ethernet

00000 — 09999

Code number as
protection against
unauthorized access to
data via one of the
interfaces;
0000 = off

Factory setting

Configuration
➔ Device data

➔ Enter defaults

No, Yes

Yes = enter factory default
setting (after entry, the
parameter automatically
returns to No)

Parameter

Value/Selection

Description